Prevention is better than a cure
Speak to our teamThe Symphony SPY10KiRTB is a 10kVA / 10000W single-phase, online double-conversion UPS designed by Uniti Power for data rooms, larger comms and network installations, healthcare and laboratory systems, industrial processes and other high-value loads. It comes as a complete 5U system, a 2U power module with a 3U battery module, and installs in a 19-inch rack or as a tower.
Because the inverter carries the load all the time, equipment is protected from power cuts, sags, surges, frequency variation and electrical noise, with no break in the output when the UPS moves to battery. Up to 95% online efficiency, ±1% output regulation and parallel operation of up to three units give larger sites both capacity and resilience.
Typical applications include data centres and server rooms, IT and telecoms networks, enterprise and edge computing, healthcare and laboratory equipment, and industrial and manufacturing systems.
The supplied 3U battery module holds 20 x 12V 9Ah batteries (240V DC), giving a typical 3.8 minutes at the full 10000W load and 9.3 minutes at 5000W. Up to five additional EBM2409RT3U external battery modules can be added, six battery modules in total, for extended runtime.
| Battery configuration | 5000W (50% load) | 10000W (full load) |
|---|---|---|
| Supplied battery module | 9.3 min | 3.8 min |
| + 1 x EBM2409RT3U | 22.6 min | 9.2 min |
| + 2 x EBM2409RT3U | 38.1 min | 15.5 min |
| + 3 x EBM2409RT3U | 55.0 min | 22.4 min |
| + 4 x EBM2409RT3U | 73.2 min | 29.8 min |
| + 5 x EBM2409RT3U | 92.5 min | 37.6 min |
The 2A charger, adjustable from 0 to 4A, recharges the supplied batteries to 90% in around 3 hours. The Run Time tab estimates runtime at any load.
Runtimes are typical values for new, fully charged batteries at 25°C, provided as a guide only. Actual runtime depends on battery age, temperature and the type of load.
With the optional SPYPK parallel card, up to three Symphony 6kVA or 10kVA units can run in parallel, either to increase capacity or to provide N+1 redundancy for loads that cannot afford downtime.
Input and output are hardwired terminal connections (L / N / PE), so the SPY10KiRTB is connected into the electrical installation rather than plugged in. The power module measures 438 x 573 x 86.2mm (2U) and the battery module 438 x 593 x 129mm (3U). Rack ears and tower feet are included, the optional SPYRAIL6-10 rail kit supports the system in a 19-inch cabinet, and the dot-matrix LCD rotates for either orientation.
The SPY10KiRTB operates from 0 to 50°C, with output derating to 50% between 40 and 50°C.
USB (HID), RS232, a programmable dry input and output, and an emergency power off (EPO) input are fitted as standard. The intelligent slot accepts an optional network management card, Modbus card or AS400 dry-contact card, and an optional WLAN module is available. WinPower G2 monitoring software provides status, alarms and controlled shutdown of connected systems.
The SPY10KiRTB is CE marked and built to IEC/EN 62040, the international standard for UPS systems. It meets Category C3 for conducted and radiated emissions, with immunity tested to IEC/EN 61000-4-2, -4-3, -4-4 and -4-5.
Registered Symphony products in the UK carry a 6-year warranty on the UPS electronics and 2 years on batteries and accessories, from the original date of purchase. Installation and commissioning is recommended but is not a condition of the warranty. See warranty information for full terms, and register your UPS once it is installed.
SPY10KiRTB 2U power module, 3U battery module, USB cable, rack ears, tower feet and user manual. Power cables are not required because input and output are hardwired. An RS232 cable and the SPYRAIL6-10 rail kit are available separately.
Does the SPY10KiRTB include batteries?
Yes. The SPY10KiRTB is supplied with a 3U battery module containing 20 x 12V 9Ah batteries.
How much load can the SPY10KiRTB support?
Up to 10000W. Its output power factor is 1.0, so the VA and watt ratings are the same.
How long will the SPY10KiRTB run on battery?
About 3.8 minutes at full load and 9.3 minutes at half load on the supplied battery module, extending to 37.6 minutes at full load and 92.5 minutes at half load with five EBM2409RT3U modules.
Can SPY10KiRTB units run in parallel?
Yes. Up to three units can be paralleled for capacity or N+1 redundancy using the SPYPK parallel card.
How is the SPY10KiRTB connected?
Through hardwired L / N / PE terminals on both input and output. Professional installation and commissioning is recommended.
How do I buy the SPY10KiRTB?
Request a quote on this page, call 0845 561 0560, or find a Uniti Power partner near you.
Runtime figures are taken from the Symphony Range Brochure (V1.2025, PDF). Full specifications are in the SPY10KiRTB datasheet (PDF).
| Product code | SPY10KiRTB |
| Form factor | 5U rack/tower convertible (2U power module + 3U battery module) |
| Power rating - capacity | 10000VA / 10000W |
| Efficiency - double conversion mode | 95% |
| Efficiency - ECO mode | 98% |
| Input - voltage range | 160-275V at 100% load; 110-160V derating linearly to 50% load |
| Input - rated frequency | 50Hz / 60Hz |
| Input - frequency range | 40-70Hz (45-55Hz / 54-66Hz at load >60%) |
| Input - power factor | >0.995 |
| Input - THDi | <3% linear load; <5% non-linear load |
| Input - connection | Hardwired terminals (L / N / PE) |
| Output - rated voltage | 220 / 230 / 240VAC |
| Output - rated frequency | 50Hz / 60Hz |
| Output - maximum power factor | 1.0 |
| Output - voltage accuracy | ±1% |
| Output - THDv | <1% linear load; <5% non-linear load |
| Output - crest factor | 3:1 maximum |
| Output - overload (line mode) | 100-105%: continuous; 105-125%: 10 minutes; 125-150%: 30 seconds; >150%: 500ms |
| Output - connection | Hardwired terminals (L / N / PE) |
| Output - load segment control | Optional |
| Transfer time - line / battery | 0ms |
| Transfer time - ECO / inverter | 10ms |
| Battery - DC voltage | 240VDC |
| Battery - internal battery | 20 x 12V / 9Ah (in 3U battery module) |
| Battery - typical backup time | 9.3 minutes at 50% load; 3.8 minutes at 100% load (internal battery, PF 1.0) |
| Battery - maximum EBMs | 5 additional (6 in total, including the supplied battery module) |
| Battery - compatible EBM | EBM2409RT3U (240V, 3U rack/tower) |
| Runtime (minutes at 5000W / 10000W) - internal battery | 9.3 / 3.8 |
| Runtime (minutes at 5000W / 10000W) - with 1 EBM | 22.6 / 9.2 |
| Runtime (minutes at 5000W / 10000W) - with 2 EBMs | 38.1 / 15.5 |
| Runtime (minutes at 5000W / 10000W) - with 3 EBMs | 55.0 / 22.4 |
| Runtime (minutes at 5000W / 10000W) - with 4 EBMs | 73.2 / 29.8 |
| Runtime (minutes at 5000W / 10000W) - with 5 EBMs | 92.5 / 37.6 |
| Charger - charging current | 2A (adjustable 0-4A) |
| Charger - recharge time | 3 hours to 90% |
| Operating modes - CVCF (frequency converter) | Yes (derating to 60% load) |
| Operating modes - parallel operation | Optional, up to 3 units |
| Display | Dot matrix LCD, manually rotatable |
| Display & communications - languages | 10 |
| Display & communications - USB | USB 2.0 with HID |
| Display & communications - RS232 | Yes, DB9 |
| Display & communications - dry I/O | 1 programmable dry input; 1 programmable dry output |
| Display & communications - EPO | Yes |
| Display & communications - intelligent slot | Yes, long card |
| Display & communications - network card | Optional, NMC long card |
| Display & communications - Modbus card | Optional, CMC/Modbus long card |
| Display & communications - dry contact card | Optional, AS400 long card |
| Display & communications - WLAN module | Optional, HDMI type |
| Display & communications - IoT Ethernet | RJ45 |
| Display & communications - monitoring software | WinPower G2 |
| Physical - dimensions (W x D x H) | Power module: 438 x 573 x 86.2mm (2U); battery module: 438 x 593 x 129mm (3U); 5U total |
| Physical - IP rating | IP20 |
| Environment - operating temperature | 0-50°C (power derates to 50% at 40-50°C) |
| Environment - nominal battery temperature | 20-25°C |
| Environment - relative humidity | 0-95% |
| Environment - operating altitude | 0-3000m (load derates 1% per 100m from 1000-3000m) |
| Environment - acoustic noise | <50dB at typical load, battery fully charged |
| Standards & certification - certification | CE, IEC/EN 62040 |
| Standards & certification - EMI (conducted / radiated) | Category C3 |
| Standards & certification - ESD | IEC/EN 61000-4-2 |
| Standards & certification - radiated immunity | IEC/EN 61000-4-3 |
| Standards & certification - EFT | IEC/EN 61000-4-4 |
| Standards & certification - surge | IEC/EN 61000-4-5 |
| In the box & accessories - input power cable | Not applicable (hardwired) |
| In the box & accessories - output power cable | Not applicable (hardwired) |
| In the box & accessories - EBM cable | Yes (supplied with EBM) |
| In the box & accessories - USB cable | Yes |
| In the box & accessories - RS232 cable | Optional |
| In the box & accessories - rail kit | Optional, SPYRAIL6-10 |
| In the box & accessories - tower feet | Yes |
| In the box & accessories - rack ears | Yes |
| In the box & accessories - manual | Yes |
How long the SPY10KiRTB runs on its supplied 3U battery module and with up to five additional EBM2409RT3U external battery modules.
| Configuration | 2.5 kW (25%) | 5 kW (50%) | 7.5 kW (75%) | 10 kW (100%) |
|---|---|---|---|---|
| Supplied battery module | 21.2 min | 9.3 min | 5.9 min | 3.8 min |
| + 1 x EBM2409RT3U | 49.6 min | 22.6 min | 13.6 min | 9.2 min |
| + 2 x EBM2409RT3U | 1 h 23 min | 38.1 min | 22.6 min | 15.5 min |
| + 3 x EBM2409RT3U | 2 h 00 min | 55.0 min | 32.7 min | 22.4 min |
| + 4 x EBM2409RT3U | 2 h 40 min | 1 h 13 min | 43.5 min | 29.8 min |
| + 5 x EBM2409RT3U | 3 h 22 min | 1 h 33 min | 54.9 min | 37.6 min |
Prevention is better than a cure
Speak to our team