Prevention is better than a cure
Speak to our teamThe TMP2200IEC is the 2200VA / 1200W model in Uniti Power's Tempo line-interactive range and the largest in the series. It is designed for small network setups, CCTV and access control systems, and multi-device workstations, with six IEC 10A outlets, automatic voltage regulation (AVR), RJ45 surge protection and two internal 12V 9Ah batteries giving an estimated 50 minutes of backup at a 100W load, the longest in the Tempo range.
When a router, a network switch and network storage share one supply, a power cut takes them all down at once. The TMP2200IEC doubles the watt capacity of the TMP1200IEC in the same tower footprint, so more equipment can be backed up from a single unit. Its boost and buck AVR keeps routine sags and surges away from the load without using the battery, and the typical 4-8ms transfer to battery covers short interruptions and gives time for an orderly shutdown.
The TMP2200IEC suits sites that need more protected capacity than a single-desk UPS:
Uniti Power's Tempo range covers 850VA to 2200VA. The TMP2200IEC is the choice where load or backup time is beyond the smaller models:
| Model | Capacity | Outlets | Data-line protection | Backup (est. 100W) |
|---|---|---|---|---|
| TMP850IEC | 850VA / 480W | 3 x IEC 10A | RJ11 | 20 min |
| TMP1200IEC | 1200VA / 600W | 6 x IEC 10A | RJ45 | 40 min |
| TMP2200IEC | 2200VA / 1200W | 6 x IEC 10A | RJ45 | 50 min |
Runtimes are typical values for new, fully charged batteries at 25°C, provided as a guide only. Actual runtime depends on battery age, temperature and the type of load.
The TMP2200IEC measures 139 x 195 x 364mm (W x H x D), weighs 10.4kg and has a noise level below 45dB. It takes power through an IEC C14 10A inlet and should be plugged into an earthed wall socket that is nearby and easy to reach. Choose a protected location with good airflow at 0 to 40°C, away from dust, damp and direct sunlight.
Charge the UPS for at least 4 hours with no load before first use, and allow at least 8 hours for the full rated backup time. Connect equipment straight to the UPS outlets rather than through a power strip or surge suppressor, and keep laser printers and other motor-driven devices off the UPS, as their in-rush current can cause damage.
The front-panel LCD shows operating mode, voltages, load level and battery charge. Audible alarms sound every 10 seconds in battery mode, every second at low battery, every 0.5 seconds on overload and continuously on a fault. Its HID USB interface works with the power management in Windows, macOS and Linux to shut a connected computer down automatically. There is no expansion slot for a network management card.
According to the Tempo user manual, the range meets IEC/EN 62040-1, IEC/EN 62040-2 and IEC/EN 62040-3. As a Category C2 UPS, the TMP2200IEC may cause radio interference in a residential environment, where additional measures may be required.
Registered Tempo products in the UK are covered by a 6-year warranty on parts and 1 year on batteries. See warranty information for full terms and register your UPS once installed. Uniti Power technical support can help with setup questions.
What is the maximum load for the TMP2200IEC?
1200W. The TMP2200IEC is rated at 2200VA with a 0.55 output power factor, so the 1200W figure is the limit to size against.
How does the TMP2200IEC differ from the TMP1200IEC?
Both use the same tower case with six outlets and RJ45 protection. The TMP2200IEC has twice the watt capacity (1200W against 600W) and larger 12V 9Ah batteries, giving an estimated 50 minutes at 100W compared with 40 minutes.
How quickly does the TMP2200IEC recharge?
About 4 hours to 90% after a complete discharge.
Is the TMP2200IEC suitable where online double conversion is required?
No. The TMP2200IEC is a line-interactive UPS with AVR and a typical 4-8ms transfer time. For an online UPS, see Uniti Power's Echo ECH2000RMi2U or Symphony SPY3000RMi2U.
How do I obtain the TMP2200IEC?
Request a quote on this page, call 0845 561 0560, or find a Uniti Power partner near you.
Specifications are taken from the Tempo Range Datasheet (PDF). See also the Tempo Range Brochure (PDF) and the Tempo User Manual (PDF).
| Product code | TMP2200IEC |
| EAN | 7864858528399 |
| Input - voltage | 230 VAC |
| Input - voltage range | 170-280 VAC |
| Input connection | IEC-C14/10A |
| Output - capacity | 2200VA/1200W |
| Output - power factor | 0.55 |
| Output - nominal voltage | 230 VAC |
| Output - voltage regulation | +/-10% (Battery Mode) |
| Output - frequency range | 50/60Hz |
| Output - frequency regulation | ±1Hz (Battery Mode) |
| Output - waveform | Stepped Sine Wave |
| Output - transfer time | Typical 4-8ms |
| Output socket | (6) IEC C13 10A |
| Efficiency - line mode | 95% |
| Efficiency - AVR mode | 88% |
| Efficiency - battery mode | 60% |
| Battery type | 12V/9AH |
| Battery - number of internal battery | 2 |
| Battery - rated battery voltage | 24V DC |
| Battery - backup time (est. 100w) | 50 min |
| Battery - recharge time (to 90%) | 4 hours to 90% after complete discharge |
| Surge suppression - RJ11 & RJ45 protection | RJ45 |
| Display - LCD | LCD Display |
| Audible alarm - backup mode | Sounding every 10 seconds |
| Audible alarm - low battery | Sounding every 1 second |
| Audible alarm - overload | Sounding every 0.5 second |
| Audible alarm - fault | Continuously sounding |
| Protection - full protection | Discharge, overcharge and overload protection |
| Physical - product dimensions WxHxD | 139 x 195 x 364 mm |
| Physical - packaged dimensions WxHxD | 236 x 304 x 458 mm |
| Physical - product weight | 10.4kg |
| Physical - packaged weight | 12.0kg |
| Environment - operating temperature | 0°c to 40°c |
| Environment - noise level | <45dB |
| Interface - USB | Yes |
| Interface - external slot | No |
| Interface - TVSS protection | Option RJ45 |
| Warranty - standard warranty | 6-year parts/1-year batteries |
How long the TMP2200IEC runs on its two internal 12V 9Ah batteries, from light load up to its full 1200W rating.
| Configuration | 100 W | 300 W (25%) | 600 W (50%) | 900 W (75%) | 1.2 kW (100%) |
|---|---|---|---|---|---|
| Internal batteries | 50.0 min | 12.1 min | 3.7 min | 2.0 min | 1.3 min |
Prevention is better than a cure
Speak to our team